Welcome to Sharetop Technology Co.,ltd.
Hotline:+86-0755-27524036
share
  qq space Sina Weibo Renren Tencent Weibo Netease Weibo More platforms
Home>Private network Case>80G Project Of Interconnection Between Different Campuses Of A University In Shandong

Private network Case

80G Project Of Interconnection Between Different Campuses Of A University In Shandong

[Author:XYTSHARETOP]  [Date:2022-06-20]  [Clicks:978] 
Campus interconnection, WDM capacity expansion, point-to-point transmission

Customer Background


The client is a 211 key university in Qingdao, Shandong Province, with two campuses in different districts. Now, due to teaching needs, an 80g optical transmission system needs to be built between the two campuses.



Business Challenges


1. only 2 cores of optical fiber are available in the two campuses, and the link length is about 70km. Due to serious aging, the optical fiber loss is very large;

2. there are many types of interconnected services, including voice, video, intranet, etc., which need to be physically isolated;

3. the switches on both sides of the customer side belong to different brands. Xianyitong also needs to be compatible with different brands of equipment on both sides of the customer side.


Solution


1. xyt-16416 active wavelength division solution is adopted, and different converters are configured to convert voice and video signals into digital optical signals for wavelength division multiplexing transmission;

2. a total of 16 wavelength division service channels are configured, with single channel transmission of 10G. 8 channels are configured to meet the customer's 80g transmission. Different services enter different wavelength division service channels, and the physical isolation between services has been achieved;

3. at the same time, one network management channel is also configured to interconnect the network management of the two devices, so as to realize remote management of the end-to-end devices;

4. optical fiber amplifiers are configured at both the transmitting and receiving ends to solve the problem of excessive optical attenuation and allow the system to have sufficient redundancy;

5. adopt different compatibility codes according to the user's switch to improve the compatibility performance.



Value Embodiment

1. from demand discussion, equipment selection, scheme determination, and after-sales on-site installation and commissioning, xianyitong provides perfect one-stop services;

2. the solution of xianyitong not only meets the existing needs of customers, but also meets the capacity expansion needs of customers in the next few years, exceeding customer expectations;

3. after the system started to operate, the optical cable was cut several times in the middle of the process, resulting in the increasing loss of optical fiber. The technical engineers of xianyitong actively cooperated with customers to solve problems;


Related Products

1. XYT-16416XYTSHARETOP Active Wavelength Division System

2. XYT-1600-ODMXYTSHARETOP Active Wavelength Division Board

3. XYT-1600-EDFAXYTSHARETOP Active Wavelength Division Fiber Amplifier

4. XYT-SFP+DW-80XYTSHARETOP 10G10G Color Light Module



NEWS
Common services
About us
Payment issue
After-sales service
Co-operatives
  • 0755-27524940
  • 0755-27524036
Privacy Policy   |   Copyright   |   Online message   |   Site map   |   sitemap   |   Download   |  Hot line:+86-0755-27524036  |   Subscribe
ShenZhen Sharetop Technology Co.,Ltd. Copyright ? 2010-2015 poptimes CO.,Ltd. All rights reserved.